Skip to content
Jupiter documentation
Menu

Test a module

Fit a cartridge and a memory module, run a test from the front panel and read the result.

Fit the cartridge and the module#

  1. Check that the module-power LED is off.
  2. Slide the Cartridge in from the rear, sockets up, until the gold fingers seat.
  3. Put the module or chip in its socket. Supported memory lists the socket for each type.
  4. Connect the tester to a USB-C PD charger.

Run a test#

The display lists the memory profiles. The bottom two lines show what each key does.

  1. Press F1 or F2 to move to the profile that matches your memory.
  2. Press F3 for the quick test or F4 for the full test.
  3. Wait while the display shows Testing. Keep the module in its socket.

Read the result#

  1. After a FAIL, press F2 for the details: the phase, the error count, the first failing address and the failing data lines.
  2. Press F1 to run the same test again.
  3. Press ESC to go back to the list.

Front panel describes every screen.

Remove the module#

  1. Wait for the result. The DUT supply is off when the module-power LED is off.
  2. Take the module out.
  3. Pull the cartridge out to the rear if you want to change it.

Source: belikh/RAMalyser HEAD